Product Overview
The PK767A1 is a high-energy, high-safety lithium iron phosphate (LiFePO₄) battery system designed specifically for industrial AGV and AMR platforms. It integrates 3.2V 21Ah cells in a 2P15S configuration (2 parallel, 15 series), delivering a nominal 48V with a rated capacity of 42Ah.
The system is equipped with an advanced Battery Management System (BMS) that monitors voltage, current, temperature, and state of charge in real time, providing comprehensive protection against overcharge, over-discharge, overcurrent, short circuit, and extreme temperatures.
A unique feature of this model is the built-in S–type aerosol fire extinguishing device – a compact, automatic fire suppression system that activates at ≥170°C, adding an extra layer of safety for mission-critical robotic applications.
Technical Specifications
| Cell Chemistry | LiFePO₄ |
| Cell Model | INF2265146-21Ah |
| Configuration | 2P15S (30 cells total) |
| Nominal Voltage | 48V |
| Rated Capacity | 42Ah @ 0.3C, 25°C |
| Minimum Capacity | 40Ah @ 0.3C, 25°C |
| Standard Charge Current | 30A (0.7C approx.) |
| Standard Discharge Current | 30A |
| Max. Continuous Discharge Current | 50A (≤10s, 15–45°C) |
| Peak Discharge Current | 100A (<20ms, 15–45°C) |
| Charge Cut-off Voltage | 54.7V (programmable; cell limit 3.65V) |
| Discharge Cut-off Voltage | 39V (programmable; cell limit 2.6V) |
| Typical Charge Time | ~1.5 hours (standard) |
| Communication Interface | RS485 (Baud rate 9600) |
| Enclosure Material | Q235 steel |
| Dimensions (L×W×H) | 443mm × 104mm × 119mm (±1mm) |
| Weight | ~15 kg |
BMS Precision & Protection
The BMS provides multi-level protection with the following key thresholds:
| Protection Type | Trigger Condition | Delay | Recovery |
| Overcharge (cell) | 3.50 – 3.70V | 1 – 3s | 3.55 – 3.65V |
| Over-discharge (cell) | 2.60 – 2.80V | 1 – 3s | 2.90 – 3.10V |
| Charge Overcurrent | 40 – 50A | 7 – 13s | 32s delay |
| Discharge Overcurrent 1 | 60 – 70A | 7 – 13s | 32s delay |
| Discharge Overcurrent 2 | 250 – 300A | 200 – 700ms | 32s delay |
| Short Circuit | – | 200 – 600μs | Charge recovery / load off 5s |
| Charge High Temp | 55 – 60°C | – | 53 – 57°C |
| Charge Low Temp | -3°C | – | 0°C |
| Discharge High Temp | 55 – 60°C | – | 55 – 60°C |
| Discharge Low Temp | -22 to -18°C | – | -8 to 12°C |
Additional BMS features:
- Cell balancing (charging mode, 40–60mA, activation at 3.35–3.45V with ≥15mV difference)
- SOC calculation with automatic learning
- Sleep mode power consumption ≤300μA
- Operating temperature range: -20°C to +70°C
Built-in Fire Suppression System
The PK767A1 includes an S-type aerosol fire extinguisher as standard equipment:
| Parameter | Value |
| Model | QRRO.01GW/S |
| Dimensions | 49.2 × 47.7 × 20 mm |
| Operating Range | -50°C to +90°C |
| Activation | Thermal (≥170°C) |
| Discharge Time | ≤6 seconds |
| Activation Lag | ≤1 second |
| Protected Volume | ≤0.3 m³ |
| Lifespan | 10 years |
This system requires no piping, no pressurised storage, and is maintenance-free – it automatically activates in case of thermal runaway, significantly improving overall system safety.
Charge / Discharge Port Design
The battery uses separate ports for charging and discharging:
Accepts charge current only.
delivers power to the load only.
Important: The two ports must never be paralleled, as this will damage the battery.
The RS485 interface allows the host controller to enable/disable the charge port, ensuring the charging brushes are de–energised when the AGV is in motion – eliminating arcing and safety risks.
Remote On/Off Control
Close the KEY line (via communication port) → battery turns on.
Open the KEY line → battery shuts down after a 10-second delay.
This enables seamless integration with the vehicle’s start/stop logic.
Communication & Data Monitoring
The RS485 interface provides real-time access to:
Total voltage, current, and remaining capacity (SOC)
Individual cell voltages (up to 15 series cells)
Multiple temperature sensor readings (NTC)
Protection status flags (over 16 alarm/protection types)
Cycle count and manufacturing date
Firmware version and hardware ID
This data enables the AGV/AMR control system to monitor battery health, predict maintenance needs, and safely manage charging/discharging operations.
Typical Applications
For logistics, warehousing, and manufacturing
For flexible material handling
Tow tractors, forklifts, and pallet movers
Where high safety and reliability are required
Operating Conditions
| Condition | Temperature Range |
| Charging | 0°C to 55°C |
| Discharging | -20°C to 60°C |
| Storage | 0°C to 45°C (optimum 15–25°C) |
Recommendation: For best cycle life, use within 15–45°C. Avoid deep discharge (keep SOC >20%) and store at 50% SOC if unused for over 1 month.
Why Choose This Battery?
No thermal runaway risk
An industry-first safety feature
50A continuous, 100A peak
Easy integration with AGV/AMR
Enhanced operational safety
Voltage, capacity, communication, and mechanical design can be adapted to your specific vehicle requirements
Notes & Warnings
- Do not parallel the charge and discharge ports.
- Use only the specified charger (54.7V CC-CV).
- Charge only when battery temperature is between 0°C and 55°C.
- Discharge only when temperature is between -20°C and 60°C.
- If the battery is not used for more than 3 months, recharge to 48V (approx. 50% SOC) and store in a cool, dry place.
- The fire extinguisher is a single-use device – contact the supplier after activation.
Ordering Information
For customisation (different capacity, voltage, connectors, or communication protocols), please provide your application details (load profile, duty cycle, ambient conditions, and desired interface). Engineering support is available for tailored solutions.
For further technical data or to request a sample, please contact our sales team.
Specifications subject to change without notice. Always refer to the latest product datasheet.