Product Overview
The PK1426A1 is a high-capacity, explosion–proof lithium iron phosphate (LiFePO₄) battery system engineered specifically for specialised industrial equipment operating in hazardous environments – including forestry logging machinery, mining equipment, oil and gas field machinery, and other applications where explosive gases, dust, or volatile conditions exist.
The system integrates 3.2V 205Ah large–format prismatic LiFePO₄ cells in a 1P8S configuration (8 cells in series), delivering a nominal 25.6V with 205Ah rated capacity – an exceptional 5.25kWh of stored energy – providing the high energy and robust power required for heavy-duty industrial operations.
The battery is housed in a purpose–built explosion–proof enclosure with an integrated explosion–proof cover and built–in fire suppression device (fire extinguishing cartridge) , providing the highest level of safety for personnel and equipment in hazardous environments.
An intelligent Battery Management System (BMS) monitors voltage, current, temperature, and state of charge in real time, providing comprehensive protection against overcharge, over-discharge, overcurrent, short circuit, and temperature extremes – ensuring safe and reliable operation in the most demanding conditions.
Technical Specifications
| Model | JYHYLFP-PH25.6V205Ah |
| Cell Chemistry | LiFePO₄ (Lithium Iron Phosphate) |
| Cell Model | JYHYLEP-205Ah (Large-format Prismatic) |
| Configuration | 1P8S (8 cells total) |
| Nominal Voltage | 25.6V |
| Rated Capacity | 205Ah @ 0.3C, 25°C |
| Minimum Capacity | 200Ah @ 0.3C, 25°C |
| Standard Charge Current | 100A |
| Charge Cut-off Voltage | 29.2V (cell limit 3.65V) |
| Standard Discharge Current | 50A |
| Discharge Cut-off Voltage | 20.8V (cell limit 2.6V) |
| Continuous Discharge Current | 80A @ 15–45°C |
| Max. Short-Term Discharge Current | 150A @ 15–45°C, ≤3s |
| Peak Discharge Current | 300A @ 15–45°C, ≤200ms |
| Standard Charge Time | ~3.5 hours |
| Cycle Life | ≥2000 cycles (to 70% capacity) |
| Communication Interface | CAN (125K baud rate) |
| Charge/Discharge Port | EV cable 25mm² – explosion-proof connector |
| Enclosure Type | Explosion-proof housing |
| Enclosure Colour | Industrial Grey |
| Dimensions (L×W×H) | 650mm × 195mm × 409mm (±1mm) |
| Weight | ~50 kg |
Communication Port Pinout – 4-Pin Connector
| Pin | Function | Pin | Function |
| 1 | KEY+ | 3 | Vehicle CAN H |
| 2 | KEY- | 4 | Vehicle CAN L |
Key features:
CAN communication – standard protocol, 125K baud rate
Key–switch control – KEY+/KEY- for remote ON/OFF
Explosion–proof connector – ensures safe connection in hazardous environments
Explosion-Proof Design & Safety Features
🔒 Explosion-Proof Enclosure
- Purpose-built explosion–proof housing (Industrial Grey finish)
- Designed to contain any internal ignition or explosion, preventing propagation to the external hazardous atmosphere
- Meets stringent safety requirements for operation in explosive environments
🧯 Built-In Fire Suppression Device (Fire Extinguishing Cartridge)
- Integrated fire extinguishing cartridge within the explosion-proof cover
- Automatically activates in the event of thermal runaway or fire
- Provides immediate suppression to prevent escalation
- Critical safety feature for forestry logging machinery and mining equipment
🛡️ Explosion-Proof Cover
- Reinforced explosion-proof cover design
- Seals the battery compartment from external ignition sources
- Prevents ingress of flammable gases, dust, and moisture
🔌 Explosion-Proof Connectors
- All external connections (power and communication) utilise explosion-proof connectors
- Ensures safe mating/unmating in hazardous atmospheres
BMS Protection & Monitoring
The BMS provides comprehensive protection with the following features:
Cell voltage monitoring, cut-off at 3.65V/cell
Prevents deep discharge, cut-off at 2.6V/cell
Dual-level protection for charge and discharge
Instantaneous response
Ensures safe operation across temperature extremes
Maintains uniform cell performance
≤ ±5%
LiFePO₄ Chemistry & Safety – Key Advantages for Hazardous Environments
| Advantage | Benefit for Forestry, Mining & Industrial Operations |
| 🔒 Explosion–Proof Design | Certified explosion-proof housing – safe operation in hazardous atmospheres |
| 🧯 Built–In Fire Suppression | Integrated extinguishing cartridge – automatic fire protection |
| 🛡️ LiFePO₄ Safety | Inherently thermally stable chemistry – no thermal runaway risk |
| 🔋 High Capacity | 205Ah / 5.25kWh – powers heavy-duty machinery for extended shifts |
| ⚡ High Power | 300A peak – handles demanding hydraulic and drive requirements |
| 🔄 2000+ Cycle Life | Exceptional longevity – reduces total cost of ownership |
| ❄️ Wide Temperature Range | -20°C to 60°C discharge – reliable in extreme outdoor conditions |
| 🏭 Robust Construction | ~50kg heavy-duty design – built to withstand vibration and shock |
Key Features
The PK1426A1 features a comprehensive safety system specifically designed for hazardous environments:
- Explosion–proof enclosure – contains internal ignition
- Explosion–proof cover – seals against external ignition sources
- Built–in fire extinguishing cartridge – automatic fire suppression
- Explosion–proof connectors – safe electrical connections in hazardous atmospheres
Remote power control via KEY+/KEY- interface:
Power ON: Short KEY+/KEY- → system powers on
Power OFF: Open KEY+/KEY- → system shuts down
Industry-standard CAN bus communication (125K baud rate) enables seamless integration with industrial equipment control systems, providing real-time battery status monitoring, fault diagnosis, and intelligent power management.
With 300A peak discharge current and 150A short–term discharge capability, this battery supports the demanding power requirements of heavy-duty forestry and industrial machinery during:
- Hydraulic system operation
- Heavy lifting and loading
- Incline climbing and traction
- Simultaneous multiple load operations
Operating Conditions
| Condition | Temperature Range |
| Charging | 0°C to 55°C |
| Discharging | -20°C to 60°C |
| Storage | 0°C to 45°C (optimum 15–25°C) |
Typical Applications
Harvesters, forwarders, skidders
Underground loaders, haul trucks, shuttle cars
Drilling equipment, pump jacks
Chemical plants, grain handling, dust-laden environments
Requiring explosion-proof certification
Operating in hazardous classified areas
Why Choose the PK1426A1 for Hazardous Environments?
Certified safe operation in hazardous atmospheres
Automatic fire extinguishing – protects personnel and equipment
5.25kWh energy – extended shift operation
Powers heavy-duty hydraulic and drive systems
Full integration with equipment control systems
Simple, reliable power management
Exceptional longevity – reduced TCO
-20°C to 60°C – reliable in extreme conditions
Professional appearance, corrosion-resistant finish
Voltage, capacity, connectors, and communication protocols can be tailored
Forestry Logging Machinery – Application Focus
Forestry operations present unique challenges for battery systems:
Dust and debris
Logging operations generate significant airborne particulates
Vibration and shock
Rough terrain and heavy machinery operation
Temperature extremes
From sub-zero winters to hot summers
Fuel ignition hazards
Potential presence of flammable vapours and dust
The PK1426A1 is specifically designed to address these challenges:
Explosion-proof enclosure
Prevents ignition of dust and vapours
Built-in fire suppression
Provides immediate protection in case of internal failure
Robust construction
Withstands the mechanical stresses of forestry operations
Wide temperature range
Ensures reliable operation in all seasons
Notes & Warnings
- Use only the specified charger (29.2V, 100A, CC-CV).
- Charge only when battery temperature is between 0°C and 55°C.
- Discharge only when temperature is between -20°C and 60°C.
- Do not over–discharge – recharge within 24 hours after full discharge.
- For storage exceeding 2 months, maintain at ~50% SOC (approx. 25.6V).
- Storage voltage per cell: 3.2–3.35V.
- Do not connect batteries in series without proper engineering assessment.
- Explosion–proof certification – the battery must be installed and used in accordance with the relevant hazardous area classification and safety regulations.
- Fire extinguishing cartridge – this is a single-use device. After activation, contact the supplier for replacement.
- Explosion–proof connectors – ensure connectors are properly mated and locked before operation. Do not mate/unmate connectors in a hazardous atmosphere when power is applied.Periodic inspection – regularly inspect the explosion-proof enclosure, seals, and connectors for damage or wear. Replace any damaged components immediately.
Ordering Information
For customisation (different capacity, voltage, connectors, communication protocols, or explosion-proof certification requirements), please provide your application details – including operating environment classification, load profile, duty cycle, and desired interface. Engineering support is available for tailored solutions.